Related Experiment Video
Updated: Jul 21, 2026

In vitro Measurements of Tracheal Constriction Using Mice
Published on: June 25, 2012
Measurement of tracheal humidity and temperature
Kristina Liener1, Jochen Durr, Richard Leiacker
1Department of Otorhinolaryngology, University of Ulm, Ulm, Germany.
Background:
After tracheostomy, patients often present with chest complaints. Measurement of objective parameters of the tracheal climate is important to evaluate 'artificial noses' or humidifying devices.
Objectives:
The purpose of this study was to present an experimental setup for measurement of tracheal temperature and humidity for possible use in clinical studies in tracheotomized patients.
Methods:
The study design was a prospective study. Patients with tracheal stoma were chosen as study participants. Tracheal temperature and humidity during the respiratory cycle were measured using a miniaturized thermocouple and a humidity sensor connected to a suction system.
Results:
Accurate measurement of tracheal temperature and humidity was feasible in patients with tracheal stoma. Tracheal humidity and temperature values measured in this study were similar to values reported earlier by other working groups.
Conclusions:
The experimental setup presented may reliably be used in the evaluation of 'artificial noses' or other passive humidifiers in tracheotomized patients.
More Related Videos
05:32A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
08:30Intraperitoneal Glucose Tolerance Test, Measurement of Lung Function, and Fixation of the Lung to Study the Impact of Obesity and Impaired Metabolism on Pulmonary Outcomes
Published on: March 15, 2018
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Physical Assessment of the Respiratory Tract I: Health History
Subjective Data
Subjective data provides vital information about the patient's health history and symptoms. This data is typically collected through interviews in which patients describe their experiences, symptoms, and concerns.
Health history and key...