Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Bioimpedance, dry weight and blood pressure control: new methods and consequences
Martin K Kuhlmann1, Fansan Zhu, E Seibert
1Renal Research Institute, New York, NY 10128, USA.
Purpose Of Review:
Chronic overhydration contributes to the development of left ventricular hypertrophy and a high cardiovascular mortality in end-stage renal disease. Assessment of dry weight is highly dependent on clinical assessment. Bioimpedance technology offers the potential to quantify body fluid compartments and to facilitate dry weight prescription. This review covers recent innovative approaches to dry weight assessment using bioimpedance technology.
Recent Findings:
Three different bioimpedance approaches to determine dry weight have been published. The normovolemic/hypervolemic slope method applies whole body multifrequency bioimpedance to assess predialysis total body extracellular fluid volume and compares the extracellular fluid volume/body weight relation at hypervolemia with the standard value in normovolemic individuals. The resistance-reactance graph method uses whole body single frequency bioimpedance for assessment of hydration state and nutritional status from height-adjusted resistance and reactance. The resulting resistance-reactance vector is set in relation to a distribution range in a normovolemic population. An alternative method uses segmental bioimpedance in the form of continuous intradialytic calf bioimpedance to record changes in calf extracellular volume during dialysis. Dry weight by this method is defined as the weight at which calf extracellular volume is not further reduced despite ongoing ultrafiltration.
Summary:
Although promising, none of these methods has gained much popularity, probably due to the difficulties in understanding bioimpedance and the lack of gold standard methods for dry weight determination. Bioimpedance will improve dry weight assessment, but further refinement of the methods as well as large-scale clinical studies to demonstrate the accuracy and the clinical value of objective dry weight determination are needed.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Hypertension and Regulation of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the diastolic...