Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Effect of first-dimension column film thickness on comprehensive two-dimensional gas chromatographic separation
Zhiyue Zhu1, James Harynuk, Tadeusz Górecki
1Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ont., Canada N2L 3G1.
Abstract:
In comprehensive two-dimensional gas chromatography (GC x GC), samples experience two-dimensional separation implemented by a modulator which helps preserve the first-dimension separation and facilitates the second-dimension separation by periodically collecting, focusing and launching the material from the primary column onto the secondary column with a different stationary phase. Column overloading in GC x GC is a considerable problem, aggravated by the fact that two columns are involved. Broad first-dimension peaks of an analyte help produce smaller fractions of the analyte in the second-dimension, reducing the chance of secondary column overloading. One of the means to generate broad peaks in the first-dimension is to use thick film primary columns. A series of primary columns of various film thickness were tested in the study, and the results indicate that when other conditions are kept constant, 1 microm film columns often provide better resolution in both first and second-dimension but at the expense of a much longer separation time; 0.1 microm is clearly inadequate for GC x GC separation; 0.5 and 0.25 microm film columns seem to be the best compromises.
More Related Videos
Related Concept Videos
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Principles Of Column Chromatography
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...