Related Experiment Video
Updated: Aug 15, 2026

Comprehensive Echocardiographic Assessment of Right Ventricle Function in a Rat Model of Pulmonary Arterial Hypertension
Published on: January 20, 2023
Systolic right ventricular function assessment by pulsed wave tissue Doppler imaging of the tricuspid annulus
David Tüller1, Martin Steiner, Andreas Wahl
1Department of Cardiology, University Hospital, Berne, Switzerland.
Background:
Systolic right ventricular (RV) function is an important predictor in the course of various congenital and acquired heart diseases. So far, tricuspid annular motion velocity in systole as obtained by pulsed wave tissue Doppler imaging (TDI) has rarely been investigated for RV function assessment in a sizeable adult patient population.
Methods:
258 individuals were included in the study. Among them, there were 107 individuals without cardiovascular disease, 71 patients with predominant RV dysfunction, 40 patients with pulmonary artery hypertension, and 40 patients with predominant left ventricular dysfunction. The reference methods for RV systolic function assessment were biplane two-dimensional echocardiography and magnetic resonance imaging (MRI; n = 31) for the calculation of RV ejection fraction (EF). Lateral tricuspid valve annular motion velocities in systole (TVlat, cm/s) were recorded using pulsed wave TDI from the apical 4-chamber view (long axis function).
Results:
RV EF as determined by biplane echocardiography correlated significantly with respective values as assessed by MRI: RVEFecho = RV EFMRI + 1.6; r2 = 0.569, p <0.0001. Using the best TVlat threshold of 12 cm/s, distinction between the group with RV dysfunction and the other groups was possible with 86% sensitivity and 83% specificity. There was a direct and significant correlation between TVlat and RV ejection fraction (p <0.0001). Using TVlat thresholds of 12 and 9 cm/s, distinction between normal RV EF (>55%), moderately reduced (30-55%) and severely reduced RV EF (<30%) was possible with 84% sensitivity and 81% specificity, respectively with 83% sensitivity and 67% specificity.
Conclusion:
Systolic long axis velocity measurement of the lateral tricuspid annulus is useful and accurate to assess RV systolic function in a broad patient population. Thresholds of 12 and 9 cm/s allow differentiation between normal, moderately reduced and severely reduced RV ejection fraction.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Pulse
The pulse serves as a clinical indicator...
