Related Experiment Video
Updated: Aug 15, 2026

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Time and tidal volume-dependent ventilator-induced lung injury in healthy rats
1University Hospitals of Geneva, Division of Anaesthiological Investigations, Geneva, Switzerland. Bernard.walder@hcuge.ch
Background And Objective:
We evaluated the effect of duration of mechanical ventilation with different tidal volumes (VT) on ventilator-induced lung injury in healthy rats.
Methods:
Anaesthetized rats were ventilated with VT between 9 and 45 mL kg[-1] for 1 or 7 h with a positive end-expiratory pressure of 2.5 cmH2O.
Results:
After 1 h, rats ventilated even with the highest applied VT (36 and 45 mL kg[minus sign]1, resulting in average peak airway pressures of 30 +/-3 and 37 +/- 4 cmH2O), had no detectable alterations in dynamic or static lung mechanics, gas exchange or pulmonary permeability, but a moderate degree of lung inflammation (neutrophil accumulation in broncho-alveolar lavage) observed in all groups. In contrast, after 3 h of ventilation, rats ventilated with the highest VT (36 and 45 mL kg[minus sign]1) died from progressive circulatory failure and high-permeability pulmonary oedema, manifested by hypoxaemia, an increased alveolar-arterial protein concentration ratio and a reduced static lung compliance (mortality rate at 7 h, 62.5% and 100%). Animals with lower VT all survived and presented no changes in the measured variables.
Conclusion:
These results in normal rats demonstrate the preponderant effect of the duration (>3 h) of 'aggressive' ventilation and the cut-off value of the level of VT applied (>27 mL kg[minus sign]1).