Clinical consequences of heparin-free hemodialysis

Rita L McGill1, Alfredo Blas, Steven Bialkin

  • 1Division of Nephrology and Hypertension, West Penn Allegheny Health System, Allegheny General Hospital, Pittsburgh, Pennsylvania, USA. rmcgill@wpahs.org

Hemodialysis International. International Symposium on Home Hemodialysis
|October 13, 2005
PubMed

Heparin-free hemodialysis (HF-HD) has been increasingly used in patients at risk for bleeding, especially in the intensive care unit (ICU). Lack of heparin can reduce solute clearances in continuous hemofiltration; the effect on HD is undefined. Failure to recognize an effect of the anticoagulation strategy upon delivered clearance could contribute to the known problem of underdialysis in the ICU. In addition, the consequences of "locking" dialysis catheters with concentrated heparin solutions are also unclear. This study was designed to define the clinically relevant consequences of HF-HD and catheter locking. In part I, we performed 200 HD treatments on inpatients, of which 100 were performed with heparin, and 100 were performed as HF-HD. We calculated prescribed and delivered Kt/V and dialysis efficiency. In part II, a separate group of 14 patients undergoing HF-HD via central venous catheters had measurement of activated partial thromboplastin time (aPTT) during the last hour of dialysis, as well as 15, 60, and 240 min after catheters were locked with 1:5000 heparin. The prescribed Kt/V was 1.74+/-0.31 for standard HD with heparin vs. 1.66+/-0.36 for HF-HD (p=ns). The delivered Kt/V was 1.42+/-0.32 vs. 1.36+/-0.38 (p=ns). Efficiency was 0.82 vs. 0.84 (p=ns). Baseline aPTT was 28+/-5 s, and increased to 126+/-54 s, 15 min after locking (p<0.0001) and to 71+/-50 s, 60 min after locking (p=0.005). By 240 min, the mean aPTT had fallen to 33+/-9 s (p=0.03), although individual values were still as high as 50 s. The HF technique does not compromise delivery of dialysis to inpatients. Increased treatment time is not necessary. Locking catheters with heparin after HF-HD resulted in prolonged unintentional anticoagulation.

Related Concept Videos

Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
Anticoagulant Drugs: Low-Molecular-Weight Heparins01:30

Anticoagulant Drugs: Low-Molecular-Weight Heparins

Hemostasis is a crucial process that prevents excessive blood loss from damaged blood vessels. It involves various mechanisms such as vasoconstriction, platelet adhesion and activation, and fibrin formation. The importance of each mechanism depends on the type of vessel injury. In contrast, thrombosis is the abnormal formation of a blood clot within the blood vessels, leading to potential complications if the clot obstructs blood flow. Thrombosis can be caused by increased coagulability of the...
Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
Dialysis01:27

Dialysis

Renal failure occurs when the kidneys lose their ability to filter waste products from the blood effectively. It can be classified into two types: acute renal failure (ARF) and chronic renal failure (CRF).
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this measurement...
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications01:25

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...