Related Experiment Video
Updated: Aug 15, 2026

Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
Path integral Monte Carlo simulation of the absorption spectra of an Al atom embedded in helium
Qian Wang1, Millard H Alexander
1Chemical Physics Program, Institute for Physical Science and Technology, and Department of Chemistry and Biochemistry, University of Maryland, College Park, Maryland 20742-2021, USA.
Abstract:
We use a multilevel path integral Monte-Carlo (PIMC) method to simulate the arrangement of He atoms around a single Al atom doped in a He cluster. High-level ab initio Al-He pair potentials and a Balling and Wright pairwise Hamiltonian model are used to describe the full potential and the electronic asymmetry arising from the open-shell character of the Al atom in its ground and excited electronic states. Our calculations show that the doping of the Al 3p electron strongly influences the He packing. The results of the PIMC simulation are used to predict the electronic excitation spectrum of an Al atom embedded in He clusters. With inclusion of tail corrections for the ground and excited states potentials, the calculated 3d<--3p spectrum agrees reasonably well with the experimental spectrum. The blueshift of the calculated spectrum associated with the 4s<--3p transition of solvated Al is about 25 nm (2000 cm-1) larger than seen in experiments on Al embedded in bulk liquid He. We predict that the spectrum associated with the 4p<--3p transition will be blueshifted by approximately 7000 cm-1 (nearly 1 eV).
More Related Videos
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
08:04Excitonic Hamiltonians for Calculating Optical Absorption Spectra and Optoelectronic Properties of Molecular Aggregates and Solids
Published on: May 27, 2020
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...