Related Experiment Video
Updated: Aug 15, 2026

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Duplex ultrasound remains a reliable test even after carotid stenting
Brian G Peterson1, G Matthew Longo, Melina R Kibbe
1Division of Vascular Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611, USA.
Abstract:
Transluminal arterial stenting reduces vessel compliance and may alter accurate interpretation of flow velocities. We reviewed duplex ultrasonography (DUS) following carotid stenting to identify criteria indicative of severe recurrent stenosis. This is a single-center retrospective review of 158 carotid stenoses treated with carotid angioplasty and stenting (CAS) from April 2001 to December 2004. DUS was obtained preoperatively, postoperatively, and at 3-month intervals thereafter. Peak systolic velocity (PSV) and end diastolic velocity (EDV) were analyzed. Mean follow-up was 12 months (range 1-40). Mean age was 71 +/- 9 years (range 51-91; 74% men, 26% women). Three patients (1.9%) developed restenosis and one (0.6%) developed an asymptomatic occlusion during follow-up. Average preoperative PSV was 373 +/- 123 cm/sec (mean +/- SD) and EDV was 148 +/- 63 cm/sec. Immediate postoperative PSV and EDV decreased by an average of 70% (average 118 +/- 45 cm/sec) and 72% (average 32 +/- 15 cm/sec), respectively. In patients free from restenosis or occlusion, these reductions (range 65-80%) were maintained throughout follow-up and remained within 1-25% of immediate postoperative values. In patients suffering restenosis or occlusion, follow-up PSV and EDV increased 34% and 28%, respectively, compared to preoperative values. PSV and EDV increased by an average of 287% and 500%, respectively, compared to immediate postoperative values. Using criteria of PSV >170 cm/sec and a 50% increase of PSV over immediate postoperative values, restenosis or occlusion was detected with 100% sensitivity and specificity in our patients. Additionally, EDV >120 cm/sec and a 50% increase in EDV over immediate postoperative values detected restenosis and occlusion with 100% sensitivity and specificity. Presumed restenosis and occlusion detected by DUS were confirmed in all cases with angiography. Restenosis or occlusion after CAS at our institution can reliably be detected by carotid duplex using cut-off values of 170 cm/sec PSV, 120 cm/sec EDV, and >50% increase over immediate postoperative values. While these criteria are applied to patients undergoing CAS at our institution, they serve only as suggested guidelines for patient populations at other centers and must be customized to each Intersocietal Commission for the Accreditation of Vascular Laboratories-accredited vascular laboratory.
More Related Videos
09:33A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias V: Evaluating Dysrhythmias
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Mitral Stenosis II: Clinical features and Diagnostic Tests
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):