Related Experiment Video
Updated: Aug 15, 2026

Evaluation of Coronary Flow Reserve After Myocardial Ischemia Reperfusion in Rats
Published on: June 28, 2019
Effects of percutaneous coronary thrombectomy with the X-sizer catheter on epicardial flow and microvascular function
Ahmet Kaya Bilge1, Yilmaz Nisanci, Ercument Yilmaz
1University of Istanbul, Istanbul Faculty of Medicine, Department of Cardiology, Istanbul, Turkey. ahmetkayabilge@hotmail.com
Insights
The X-SIZER catheter effectively reduced distal embolization in acute coronary syndromes. This thrombectomy method proved safe and comparable to conventional percutaneous transluminal coronary angioplasty (PTCA) in improving coronary blood flow.
Area of Science:
- Cardiology
- Interventional Cardiology
- Vascular Medicine
Background:
- Slow coronary flow and distal embolization remain significant challenges during percutaneous coronary intervention (PCI), particularly with intracoronary thrombus.
- Effective management of thrombus is crucial for improving outcomes in acute coronary syndromes (ACS).
Purpose of the Study:
- To evaluate the effectiveness and early results of thrombectomy using the X-SIZER catheter system in patients with ACS and intracoronary thrombus.
- To compare the outcomes of X-SIZER thrombectomy with conventional percutaneous transluminal coronary angioplasty (PTCA).
Main Methods:
- A study involving 29 patients with ACS and intracoronary thrombus.
- Patients were divided into two groups: one treated with X-SIZER thrombectomy (14 patients) and the other with conventional PTCA (15 patients).
- Outcomes assessed included Thrombolysis in Myocardial Infarction (TIMI) flow and Myocardial Blush Grade (MBG).
Main Results:
- Both X-SIZER thrombectomy and conventional PTCA significantly improved TIMI flow and MBG (p<0.001).
- TIMI 3 flow was maintained in 71.4% of X-SIZER patients and 73% of PTCA patients.
- Postprocedural MBG 3 was achieved in 64.3% of X-SIZER patients versus 45% of PTCA patients.
- No significant difference in microvascular function was observed between the groups.
- Tirofiban use did not provide additional flow improvement.
Conclusions:
- X-SIZER thrombectomy is a safe and effective adjunct to primary PCI for preventing distal embolization in ACS patients with intracoronary thrombus.
- The X-SIZER system demonstrates comparable efficacy to conventional PTCA in improving epicardial and microvascular flow in this patient population.
Abstract:
During percutaneous coronary intervention, slow coronary flow and distal embolization are still important problems, especially in cases with intracoronary thrombus. The aim of this study was to learn the effectiveness and early term results of thrombectomy with the X-SIZER catheter system in acute coronary syndrome. Twenty-nine patients (22 [76%] men; 55.9 +/- 11.1 years) with acute coronary syndrome and intracoronary thrombus detected in coronary angiography were included into the study. X-sizer thrombectomy was applied to 14 of the patients, and conventional percutaneous transluminal coronary angioplasty (PTCA) was applied to the others. Baseline characteristics were similar in both groups. Mean thrombolysis in myocardial infarction (TIMI) flow increased from 0.8 +/- 0.9 to 2.4 +/- 0.6 in X-sizer-treated patients (p<0.001) and TIMI 3 flow was maintained in 71.4% of the patients. Similary, mean TIMI flow increased from 0.36 +/- 0.81 to 2.73 +/- 0.47 in conventional PTCA-treated patients (p<0.001) and TIMI 3 flow was maintained in 73% of the patients (NS). Mean myocardial blush grade (MBG) increased from 0.7 +/- 0.7 to 2.6 +/- 0.6 in X-sizer-treated patients (p<0.001) and from 0.27 +/- 0.65 to 2.36 +/- 0.67 in the conventional PTCA-treated patients (p<0.001). Postprocedural MBG 3 was obtained in 64.3% of X-Sizer-treated patients and in 45% of controls. Although microvascular function in the thrombectomy-applied patients was found better, there was no significant difference between the two groups. Furthermore it was detected that the use of tirofiban yielded no additional improvement in epicardial and microvascular flow. In acute coronary syndromes, use of X-sizer in addition to primary percutaneous coronary interventions is a safe and relatively effective method in the prevention of distal embolization.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome I: Introduction