(29)Si NMR in LC-NMR analysis of silicones

Vratislav Blechta1, Jan Sýkora, Jirí Hetflejs

  • 1Institute of Chemical Process Fundamentals, Academy of Sciences of the Czech Republic, Rozvojová 135, Prague 6, Suchdol 16502, Czech Republic.

Related Concept Videos

Silica Gel Column Chromatography: Overview01:10

Silica Gel Column Chromatography: Overview

Silica gel column chromatography is a technique for separating compounds using a column packed with silica gel as the stationary phase. This method relies on differences in the polarity of compounds. Based on their polarities, compounds move between the stationary phase (silica gel) and the mobile phase (the solvent), forming discrete bands in the column.
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution00:52

¹H NMR of Conformationally Flexible Molecules: Temporal Resolution

At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)01:19

2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)

Heteronuclear single-quantum correlation spectroscopy (HSQC) is a 2D NMR technique that reveals one-bond correlations between hydrogen and a heteronucleus. The HSQC experiment is similar to the heteronuclear correlation experiment (HETCOR) but is more sensitive. In the HSQC spectrum, the proton chemical shift is plotted on the horizontal F2 axis, while the 13C chemical shift is plotted on the vertical F1 axis. The corresponding proton and 13C spectra are also shown. The HSQC contour plot does...
Spectroscopy of Carboxylic Acid Derivatives01:26

Spectroscopy of Carboxylic Acid Derivatives

Infrared spectroscopy is primarily used to determine the types of bonds and functional groups. In carboxylic acid derivatives, a typical carbonyl bond absorption is observed around 1650–1850 cm−1. For esters, the absorption is recorded at around 1740 cm−1, while acid halides show the absorption at about 1800 cm−1. Another acid derivative, the acid anhydrides, exhibit two carbonyl absorption around 1760 cm−1 and 1820 cm−1, arising from the symmetrical and unsymmetrical carbonyl vibration.
In the...
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR01:15

¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR

The axial and equatorial protons in cyclohexane can be distinguished by performing a variable-temperature NMR experiment. In this process, except for one proton, the remaining eleven protons are replaced by deuterium. The deuterium substitution avoids the possible peak splitting caused by the spin-spin coupling between the adjacent protons. The remaining proton flips between the axial and equatorial positions.
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process: