[The factors affecting the risk for the loss of resin-bonded bridges]
B Haastert1, R Hickel, T Holste
1Klinik und Poliklinik für Zahn-, Mund- und Kieferheilkunde der Universität zu Köln.
Abstract:
1310 three-unit resin-bonded bridges were examined for their failure rates. After five years 86% (+/- 4%) were still in situ. 64% (+/- 5%) didn't need rebonding. Significant prognostic factors were: preparation of abutments, surface treatment (net retention, silicoating), type of luting agent (Bis GMA) and mobility of the abutments.