Gas chromatography with atomic emission detection for dimethylselenide and dimethyldiselenide determination in waters
Natalia Campillo1, Nerea Aguinaga, Pilar Viñas
1Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, Spain.
Abstract:
Dimethylselenide (DMSe) and dimethyldiselenide (DMDSe) were determined in plant and water samples by capillary gas chromatography using microwave induced-plasma atomic emission spectrometry for detection. The analytes were leached from the solid samples into methanol by using an ultrasonic probe, and a portion of the extract was preconcentrated by means of a purge-and-trap system before being chromatographed. The analytes were directly purged from the water samples in the presence of 6% (v/v) methanol. Element-specific detection and quantification was carried out by monitoring the selenium (196 nm) emission line. Calibration curves were obtained by plotting peak area versus concentration and the correlation coefficients for linear calibration were 0.9999 for both analytes. Detection limits of 0.8 and 1.1 ng l(-1) were obtained for DMSe and DMDSe, respectively, for water samples. For plant materials, the detection limits calculated for 0.5 g samples were 0.3 and 0.4 ng g(-1) for DMSe and DMDSe, respectively. Concentration levels of DMSe ranging from 1.2 to 4.2 ng g(-1) were found in some of the plant materials analyzed. No DMDSe was found in any of the samples. The accuracy of the method was checked by analyzing different spiked water and plant samples.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...