Related Experiment Video
Updated: Aug 14, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Capillary-channeled polymer (C-CP) fibers as a stationary phase in microbore high-performance liquid chromatography
Rayman D Stanelle1, Massimiliano Mignanelli, Phil Brown
1Department of Chemistry, Biosystems Research Complex, Clemson University, Clemson, SC 29634, USA.
Abstract:
Microbore columns utilizing polypropylene capillary-channeled polymer (C-CP) fibers as the stationary phase in high-performance liquid chromatography (HPLC) have been investigated. The polypropylene C-CP fiber diameter is approximately 50 microm, with eight channels along the periphery of the fiber ranging in diameter from approximately 12 to 35 microm. The polypropylene C-CP fibers were packed into fluorinated ethylene propylene (FEP) tubing, 1.3 mm inner diameter, with lengths of 500, 750, and 1,000 mm, to examine the effects of increased column length with regards to plate height, resolution and analysis time. The low backpressures characteristic of the C-CP fiber stationary phases allow the length of the column to be increased without significantly decreasing the specific permeability. The high specific permeability (approximately 5x10(-8) cm2) of the C-CP packed microbore columns yields a relatively low backpressure of 2.35 MPa at the highest flow rate of 17 microL/s (54 mm/s) for a 1,000 mm column. Radial compression of the soft-walled FEP tubing is accomplished by pulling the 1.7 mm o.d. column through a 1.4 mm diameter orifice. Reducing the inner diameter of the column from 1.3 to 1.0 mm lowered the interstitial fraction from 47% to 42%, decreased the A-term contributions to band broadening, resulted in a significant decrease in average plate height (approximately 30%), and increased resolution (approximately 36%) at identical linear velocities. Although the lower void volume of the radially compressed column increased the backpressure from 0.57 to 2.11 MPa at a linear velocity of approximately 20 mm/s, the specific permeability only decreased from approximately 7x10(-8) to 4x10(-8) cm2.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...