[Design and application of the framework to prevent fracture of the magnetic denture]
Bin Wei1, Wei-dong Jiang, Fu-qiang Zhang
1Department of Prosthodontics, School of Stomatology, Ninth People's Hospital, Shanghai Jiaotong University, China.
Purpose:
To investigate the methods to prevent magnetic denture from fracture.
Methods:
17 cases were selected and divided into group A and group B. 9 cases in group A only used resin base, 8 cases in group B were strengthened with frameworks. The rates of fracture or fissure in denture base were observed for 5 years, Chi(2) test was used for statistical analysis.
Results:
In group A, 3 cases were found with damaged base, there was no fracture happened in group B. Chi(2) test showed that there was significant difference between the two groups (P<0.05).
Conclusion:
Frameworks should be designed to improve the strength of the magnetic denture base. It is easy to manufacture and apply with satisfactory clinical effects.