The effects of enhanced external counterpulsation on myocardial perfusion in patients with stable angina: a multicenter radionuclide study
Related Experiment Video
Updated: Aug 14, 2026

Coronary Angiography During Ex-Situ Heart Perfusion in a Porcine Model
Published on: July 12, 2024
Andrew D Michaels1, Ajit Raisinghani, Ozlem Soran
1Division of Cardiology, University of California, San Francisco Medical Center, San Francisco, California 94143-0124, USA. andrewm@itsa.ucsf.edu
Background:
Enhanced external counterpulsation (EECP) reduces angina and extends time to exercise-induced ischemia in patients with symptomatic coronary disease. One- and two-center studies and a retrospective case series reported that EECP improves myocardial perfusion in stable angina pectoris. We sought to critically evaluate and quantify the effect of EECP on myocardial perfusion.
Methods:
In 6 US university hospitals, EECP was performed for 35 hours in patients with class II to IV angina who had exercise-induced myocardial ischemia. Symptom-limited quantitative gated technetium Tc 99m sestamibi single photon emission computed tomography exercise perfusion imaging was performed at baseline and 1 month post-EECP. Sestamibi was injected at the same heart rate in both stress tests. Single photon emission computed tomography images were read at a blinded core laboratory.
Results:
Thirty-seven patients were enrolled, 34 of whom completed pre- and post-EECP stress testing. The mean age was 61 +/- 10 years, 81% were male, 78% had prior revascularization, and 68% had 3-vessel disease. The mean angina class decreased from 2.7 +/- 0.7 at baseline to 1.7 +/- 0.7 after EECP (P < .001). Exercise duration increased from 9.1 +/- 3.7 minutes at baseline to 10.2 +/- 3.6 minutes post-EECP (P = .03). The average percentage of tracer uptake, magnitude of reversibility, average thickening fraction, and the left ventricular ejection fraction remained unchanged after EECP.
Conclusions:
We confirm previous report that EECP reduces angina and improves exercise capacity. There were no significant changes in mean defect magnitude, amount of reversibility, thickening fraction, and ejection fraction measured using myocardial quantitative single photon emission computed tomography imaging when compared at identical pre- and post-EECP heart rates.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Angina V: Nursing Management