Simultaneous analysis of human plasma catecholamines by high-performance liquid chromatography with a reversed-phase triacontylsilyl silica column
Related Experiment Video
Updated: Aug 14, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Maiko Machida1, Ayumi Sakaguchi, Satoshi Kamada
1Department of Pathophysiology, Hokkaido College of Pharmacy, 7-1 Katsuraoka, Otaru 047-0264, Hokkaido, Japan.
Abstract:
The clinical importance of simultaneous analysis of 3,4-dihydroxyphenylglycol with other human plasma catecholamines has been investigated to better understand the sympathetic nervous system. However, previous reports have had analytical difficulties with both resolution and extraction. The current study uses a reversed-phase triacontylsilyl silica (C30) column under the mobile phase condition without ion-pair reagents to separate catecholamines and their metabolites, with above 91% recoveries for intra-assay, above 85% for inter-assay, and less than 10% (n=5) coefficient of variation. Lower detection limits (S/N=4) and quantification limits (S/N=6) were 40 and 100 pg/mL for norepinephrine, 3,4-dihydroxyphenylglycol, and 3,4-dihydroxyphenylalanine, 10 and 20 pg/mL for epinephrine, 10 and 40 pg/mL for dopamine. Linear ranges were from 40 to 5000 pg/mL for norepinephrine and 3,4-dihydroxyphenylalanine, from 100 to 5000 pg/mL for 3,4-dihydroxyphenylglycol, and from 10 to 2000 pg/mL for epinephrine and dopamine. The C30 column may prove clinically useful, as it provides a convenient and simultaneous method of evaluation of human plasma catecholamines.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...