Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
[A measuring device for calculating electrical impedance of the heart in clinical conditions]
Abstract:
Changes in the electrical impedance of tissue can indicate structural changes. This suggests a technique for the noninvasive detection of allograft rejection after heart transplantation. The direct electrical connection to the heart and the application of a measuring current to the myocardium requires a high standard of safety. A device was developed for measuring cardiac impedance using a sinusoidal current of 20 microA at a frequency of 15 kHz. The control logic ensures a slow current onset and also an immediate cessation in case of conductor fracture or excessive voltage. Initial results in patients with normal recovery after heart transplantation revealed a rapid drop in impedance to about 70% of the initial value in the 1st 48 hours and then a stable course. In the sole rejection episode observed so far, the impedance increased again to 85% of the initial value. This paper discusses the technical safety requirements and the design of the device, and presents initial results of clinical examinations.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
04:05Clinical Application of Phase Angle and BIVA Z-Score Analyses in Patients Admitted to an Emergency Department with Acute Heart Failure
Published on: June 30, 2023
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Voltmeter
An ideal voltmeter would have infinite resistance, so connecting it between two points in a circuit would not alter any of the currents. Real voltmeters always have finite...
Bode Plots Construction
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Dysrhythmias V: Evaluating Dysrhythmias