Related Experiment Video
Updated: Aug 14, 2026

Rotating the Intraocular Lens to Prevent Posterior Capsular Opacification in Cataract Surgeries
Published on: July 7, 2023
Influence of optic edge design, optic material, and haptic design on capsular bend configuration
Stefan Sacu1, Oliver Findl, Rupert Menapace
1Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
Purpose:
To assess and classify capsular bend configuration at the optic rim and its association with posterior capsule (PCO) and anterior capsule opacification (ACO) and capsulorhexis contraction with various intraocular lenses (IOLs).
Setting:
Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
Methods:
A total of 659 post-cataract surgery eyes of 370 patients from different prospective randomized studies were evaluated. All eyes had standardized phacoemulsification surgery with implantation of an IOL in the capsular bag. The IOLs had a sharp or round optic edge design and were made of silicone, acrylic, or poly(methyl methacrylate) optic materials. One year postoperatively, the configuration of the capsular bend at the optic rim was assessed at the slitlamp, and standardized slitlamp images of ACO and fibrotic PCO were taken. One week, 1 year, and 3 years postoperatively, digital retroillumination images were taken for objective quantification of regeneratory PCO and the capsulorhexis area. The outcome measures were the type of capsular bend configuration, ACO score (0% to 100%), regeneratory PCO score (0 to 10), fibrotic PCO score (0 to 3), and amount of capsulorhexis contraction (mm(2)).
Results:
Four main types of capsular bend configuration were classified: parallel, "Y," right angle, and wrapping. The right-angle type was observed in the most cases (52%). Eyes with a wrapping capsular bend configuration had significantly less PCO, more capsulorhexis contraction, and more ACO than eyes with the other configurations. Wrapping capsule configuration was seen most often (55%) in round-edged silicone IOLs that had a thin optic rim.
Conclusion:
The design and material of IOLs influenced the long-term capsular bend configuration at the optic rim. The right-angle type was the most common capsular bend configuration. Intraocular lenses with silicone optic material and a thin optic rim caused a wrapping capsule configuration and resulted in more capsulorhexis contraction and ACO, but less PCO.
Related Concept Videos
Mechanisms of Membrane-bending
Membrane bending can happen due to intrinsic changes in lipid composition or extrinsic association with different proteins. The proteins involved...
Deformations in a Symmetric Member in Bending
When the member is segmented into tiny cubic elements, it is observed that the primary stress...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Stress Concentrations in Circular Shafts
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive force...