Related Experiment Video
Updated: Aug 7, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Quality assurance methods and procedures used to verify consistency in calculating dose coefficients
1Idaho State University, Pocatello, ID 83209, USA.
Abstract:
The development of a spallation neutron source with a mercury target will lead to the production of rare radionuclides. The dose coefficients for many of these radionuclides have not yet been published. A collaboration of universities and national labs has taken on the task of calculating dose coefficients for the rare radionuclides using the software package DCAL. The working group developed a procedure for calculating dose coefficients and a quality assurance (QA) program to verify the calculations completed. The first portion of this QA program was to verify that each participating group could independently reproduce the dose coefficients for a known set of radionuclides. The second effort was to divide the group of rare radionuclides among the independent participants in a manner that assured that each radionuclide would be redundantly and independently calculated, and the results subsequently be submitted for publication in a separate manuscript. The final aspect of this program was to resolve any discrepancies arising among the participants as a group. The output of the various software programs for six QA radionuclides, 144Nd, 201Au, 50V, 61Co, 41Ar, and 38S were compared among all members of the working group. Initially, a few differences in outputs were identified. This exercise identified weaknesses in the procedure, which has since been revised. After the revisions, dose coefficients were calculated and compared to published dose coefficients with good agreement. The present efforts involve generating dose coefficients for the rare radionuclides anticipated to be produced from the spallation neutron source should a mercury target be employed.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Data Validation
Key parameters for method validation include:
Dosage Regimens: Designs and Approaches
Dose Size and Dosing Frequency: Determination Methods
Dosage Interval and Administration Route: Determination Methods
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses