Related Experiment Video
Updated: Aug 14, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Development of quantitative structure gas chromatographic relative retention time models on seven stationary phases
Yawei Wang1, An Li, Hanxia Liu
1State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085, China.
Abstract:
Quantitative structure retention relationships (QSRRs) were developed to predict the gas chromatographic (GC) relative retention times (RRTs) for 209 polybrominated diphenyl ether (PBDE) congeners using the heuristic method included in the computer software Comprehensive Descriptors for Structural and Statistical Analysis (CODESSA). A total of 445 constitutional, topological, geometrical, electrostatic, and semi-empirical quantum chemical descriptors were derived for all PBDEs. Using experimental RRT data for 126 PBDE congeners from the literature, predictive regression models were built for seven individual GC capillary columns differing in stationary phases. Each model includes four descriptors which included Wiener index, Randic index, polarity parameter, etc., selected by CODESSA. High predictability was obtained. High multiple correlation coefficients R(2) indicated that >98.5% (except for stationary phase CP-Sil 19) of the total variation in the predicted RRTs is explained by the fitted models. The models were subsequently used to predict the RRTs of the remaining 83 PBDE congeners on seven different stationary phases. The statistical results show that, compared with others, DB-XLB column not only produces the least number of peak overlaps but also results in shorter retention times.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chromatographic Methods: Terminology
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
NMR Spectroscopy of Benzene Derivatives
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...

