A quadruply hydrogen bonded heterocomplex displaying high-fidelity recognition

Taiho Park1, Eric M Todd, Shoji Nakashima

  • 1Department of Chemistry, Roger Adams Laboratory, 600 South Mathews Avenue, University of Illinois, Urbana, Illinois 61801, USA.

Related Concept Videos

Molecules with Multiple Chiral Centers02:25

Molecules with Multiple Chiral Centers

Molecules that possess multiple chiral centers can afford a large number of stereoisomers. For instance, while some molecules like 2-butanol have one chiral center, defined as a tetrahedral carbon atom with four different substituents attached, several molecules like butane-2,3-diol have multiple chiral centers. A simple formula to predict the number of stereoisomers possible for a molecule with n chiral centers is 2n. However, there can be a lower number where some of the stereoisomers are...
¹H NMR: Complex Splitting01:13

¹H NMR: Complex Splitting

A proton M that is coupled to a proton X results in doublet signals for M. However, NMR-active nuclei can be simultaneously coupled to more than one nonequivalent nucleus. When M is coupled to a second proton A, such as in styrene oxide, each peak in the doublet is split into another doublet.
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied first.
IR Frequency Region: Fingerprint Region01:03

IR Frequency Region: Fingerprint Region

IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the C=O, C=N, and C=C occur between 1600–1850 cm−1.
The...
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Methods of Classification and Identification01:28

Methods of Classification and Identification

Bacterial identification relies on a diverse array of techniques to classify and understand microorganisms, each tailored to uncover specific characteristics. Traditional morphological approaches, while still valuable, are limited for closely related or structurally simple organisms. Modern methods integrate biochemical, serological, genetic, and advanced molecular tools to achieve greater accuracy.Morphological and Biochemical TechniquesMorphological characteristics, such as cell shape and...
Rapid Identification of Pathogens01:25

Rapid Identification of Pathogens

MALDI-TOF MS has transformed clinical microbiology by offering a rapid and reliable method for pathogen identification. The traditional approach to microbial identification typically involves time-consuming culture techniques and biochemical tests, which can delay the initiation of appropriate antimicrobial therapy. MALDI-TOF MS avoids these delays by using characteristic ribosomal protein mass patterns of microbial cells, enabling accurate species-level identification within minutes.Principle...