Related Experiment Video
Updated: Aug 14, 2026

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
Published on: December 9, 2010
The optimal analysis of MRI data to quantify the distribution of a microbicide
Kurt T Barnhart1, E Scott Pretorius, David M Shera
1Penn Fertility Care, Department of Obstetrics and Gynecology, University of Pennsylvania, Philadelphia, 19104, USA. kbarnhart@mail.obgyn.upenn.edu
Objective:
The objective of this study was to systematically review the use of MRI for the evaluation of deployment characteristics of vaginal microbicides and to understand the relationship of gel spread with potential influencing factors.
Methods:
Data from four clinical trials that used MRI to assess the deployment of a vaginal gel were combined. A linear mixed model best represented the spread of gel over time. Significant covariates that influence vaginal gel spread are baseline dimensions of the vagina, time from insertion, gel type, ambulation and volume of gel.
Results:
These data demonstrate that MRI has outstanding intraperson validity and reproducibility. Therefore, paired design, using linear modeling adjusting for significant covariates, is the most efficient study design for comparison of products or volumes. Division of the vagina into two distinct anatomical regions best explains difference in gel spread, i.e., upper area (above the pelvic diaphragm) and lower area (below pelvic diaphragm).
Conclusion:
We conclude that the concept of spread from the cervix to the introits, in one dimension, is inadequate to explain spread of gel due to the complex shape of the vagina.
More Related Videos
09:04In Vivo Tracking of Edema Development and Microvascular Pathology in a Model of Experimental Cerebral Malaria Using Magnetic Resonance Imaging
Published on: June 8, 2017
15:28A Microscopic Phenotypic Assay for the Quantification of Intracellular Mycobacteria Adapted for High-throughput/High-content Screening
Published on: January 17, 2014