Some aspects involving the use of CdTe for finding end-point energies in diagnostic radiology
1Department of Physics, California State University Dominguez Hills, Carson, CA 90747, USA. krmar@im.ns.ac.yu
Abstract:
We have considered the use of CdTe detectors and commercially available spectroscopy systems for the determination of the end-point energies of diagnostic X-ray devices. A simple technique based upon filtered spectra and simple fitting procedures was used to deduce end-point energies. We observed some unexpected detector-related effects such as significant shifts in the energy calibration at high count rates. When CdTe detectors operate at high counting rates drifts in the DC level, associated with collection rates of the positive charge (holes) can yield a corresponding shift in the spectrum towards lower energies. Only for relatively low counting rates and long detection periods, in excess of 10 min, can end-point energies be obtained with CdTe that reach levels of precision found in recent protocols. High rates also decrease energy resolution and lower the accuracy of recalibrations using characteristic X-rays from the target.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 3, 2013
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET