Is disinfection of mechanical ventilation tubing needed at home?
Michel Toussaint1, Marc Steens, André Van Zeebroeck
1Centre for Home Mechanical Ventilation Z.H. Inkendaal and Excellence Centre for Neuromuscular Disorders, Inkendaalstraat 1, 1602 Vlezenbeek, Brussels, Belgium. michel.toussaint@inkendaal.be
Introduction:
Home mechanical ventilation is used to treat chronic alveolar hypoventilation. Maintenance protocols for home ventilation circuits (HVC) remain empirical and unproven. We have investigated (1) the cleanliness and sterility of the HVC used by home ventilated patients and (2) the efficiency of tubing cleaning and decontamination protocols recommended to them and used for 12 months or more.
Method:
HVC cleanliness was assessed in 39 severe restrictive ventilated patients (16 (T) tracheostomy vs. 23 (N) noninvasive) and in 7 new valves as control. In the first experiment (Exp1), a visual and bacteriologic inspection of the expiratory valve (Eva) was conducted during a consultation in our centre. Eva visual cleanliness was assessed on a 10-point scale and Eva bacteriologic contamination analysis was performed on a dry smear. In the second experiment (Exp2), these analyses were repeated after a cleaning sequence chosen at random, either chemical (ammonium-chlorhexidine complex) (A) or mechanical by dishwasher (B).
Results:
In Exp1, 69% of Eva were dirty. Dirtiness was worse in (T) than in (N) (5.3 vs. 2; p<0.001). There was a significant positive correlation between visual cleanliness and bacteriologic contamination (r=0.56; p<0.001). Eva in group (T) were more contaminated than in group (N) (p<0.001). Eva contamination rates reached 22% in group (N) but without the presence of any potentially pathogenic organisms (PPO) and 81% in group (T) where 19% were PPO. In Exp2, EVA visual cleanliness was better after dishwasher cleaning (B) compared to chemical (A) (0.16 vs. 1.05; p<0.001) with similar bacteriological decontamination.
Conclusion:
HVC from noninvasive ventilated patients are dirty but not contaminated by PPO. We recommend washing them in a dishwasher or with detergent and hot water without specific disinfection. PPO contaminated 1/5 of invasive HVC, for which we recommend dishwasher cleaning. Decontamination is only indicated when tubing is visually very dirty or/and when tracheostomized patients are particularly sensitive to respiratory tract infections. The expiratory valve must be carefully washed specifically, with care that its balloon is not placed under water.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Tracheostomy Suctioning II: Procedure
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...