Peripheral blood pressure changes induced by dobutamine do not alter BOLD signals in the human brain
Heng Liu1, Charles Rainey, Kathryn K Lauer
1Department of Biophysics, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI 53226, USA.
Abstract:
In extending the use of functional MRI to neuropharmacology, a primary area of concern is that peripheral blood pressure changes induced by pharmacological agents could independently produce a change in the blood oxygenation level-dependent (BOLD) signal, resulting in difficulties distinguishing or interpreting drug-induced neural activations. In the present study, we utilized intravenous dobutamine, a beta-adrenergic receptor agonist, to increase the mean arterial blood pressure (MABP), while examining the effects of MABP changes on the BOLD signal in cocaine-dependent participants. Dobutamine infusion significantly increased the MABP from 93 +/- 8 mm Hg to 106 +/- 12 mm Hg (P < 0.0005), but did not produce a significant global BOLD signal. Yet, a few voxels in the anterior cingulate showed BOLD signal changes that paralleled the changes in blood pressure (BP). Our observations support the conclusion that following the infusion of psychoactive agents, brain BOLD signals accurately reflect neuronal activity, even in the face of relatively large peripheral cardiovascular effects that transiently increase systemic BP.
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart beats)...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: