Related Experiment Video
Updated: Jul 15, 2026

Standards for Quantitative Metalloproteomic Analysis Using Size Exclusion ICP-MS
Published on: April 13, 2016
Development and evaluation of a standard method for the quantitative determination of elements in float glass samples
Christopher Latkoczy1, Stefan Becker, Marc Dücking
1Swiss Federal Institute of Technology Zurich (ETH Zurich), Laboratory of Inorganic Chemistry, Wolfgang-Pauli-Strasse 10, 8093 Zurich, Switzerland. Latkoczy@inorg.chem.ethz.ch
Abstract:
Forensic analysis of glass samples was performed in different laboratories within the NITE-CRIME (Natural Isotopes and Trace Elements in Criminalistics and Environmental Forensics) European Network, using a variety of Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) systems. The main objective of the interlaboratory tests was to cross-validate the different combinations of laser ablation systems with different ICP-MS instruments. A first study using widely available samples, such as the NIST SRM 610 and NIST SRM 612 reference glasses, led to deviations in the determined concentrations for trace elements amongst the laboratories up to 60%. Extensive discussion among the laboratories and the production of new glass reference standards (FGS 1 and FGS 2) established an improved analytical protocol, which was tested on a well-characterized float glass sample (FG 10-1 from the BKA Wiesbaden collection). Subsequently, interlaboratory tests produced improved results for nearly all elements with a deviation of < 10%, demonstrating that LA-ICP-MS can deliver absolute quantitative measurements on major, minor and trace elements in float glass samples for forensic and other purposes.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab