Towards the solution of the eluent elimination problem in high-performance liquid chromatography-infrared
Krisztina István1, Róbert Rajkó, Gábor Keresztury
1Chemical Research Center, Hungarian Academy of Sciences, P.O. Box 17, H-1525 Budapest, Hungary.
Abstract:
The high-performance liquid chromatography-infrared spectroscopy (HPLC-IR) technique utilizing on-line flow through cell (FTC) detection has an inherent practical problem: strong absorption bands of the eluent may mask valuable analytical regions of the IR spectrum. The experimentalists' answer to this challenge is physical elimination of the chromatographic eluent before spectroscopic detection, which however results in off-line measurement of spectra. In the present work, the capabilities of some chemometric algorithms using iteratively applied multi-way methods such as parallel factor analysis (PARAFAC) and PARAFAC2, developed with the aim of overcoming the problems of eluent elimination are examined and evaluated. Test calculations done on simulated liquid chromatographic infrared (LC-IR) data cubes have shown that although PARAFAC2 performs much better than the simple PARAFAC method, it does not give correct decompositions, just like multivariate curve resolution with alternative least squares (MCR-ALS) and related bilinear data based methods. In search for a better solution, a method named objective subtraction of solvent spectrum with iterative use of PARAFAC and PARAFAC2 (OSSS-IU-PARAFAC and OSSS-IU-PARAFAC2) has been developed. Calculations performed with the corresponding Matlab program developed by the authors and run with the appropriate functions in PLS_Toolbox yielded very promising results in evaluations of both simulated and real HPLC-IR data sets, after necessary data pretreatments.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Chromatographic Methods: Terminology
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...