Related Experiment Video
Updated: Aug 13, 2026

A Continuous-flow Photocatalytic Reactor for the Precisely Controlled Deposition of Metallic Nanoparticles
Published on: April 10, 2019
Simultaneous determination of titanium and molybdenum in steel samples using derivative spectrophotometry in neutral
Anitha Varghese1, A M A Khadar, Balakrishna Kalluraya
1Department of Chemistry, Mangalore University, Mangalagangothri, Mangalore 574199, India.
Abstract:
A simple, selective and sensitive spectrophotometric method has been developed for the individual and simultaneous determination of Ti(IV) and Mo(VI) using resacetophenone p-hydroxybenzoylhydrazone (RAPHBH) in presence of Triton X-100, without any prior separation. Beer's law is obeyed between 0.13-1.2 microg mL-1 and 0.18-1.90 microg mL-1 concentration of Ti(IV) and Mo(VI) at 455 nm and 405 nm, respectively. The molar absorptivity and Sandell's sensitivity of the coloured complexes at pH 3.0 are 3.1x10(4) L mol-1 cm-1, 4.2x10(4) L mol-1 cm-1, and 1.6 ng cm-2, 2.3 ng cm-2 for Ti(IV) and Mo(VI), respectively. The stoichiometry of the complexes were found to be 1:2 and 1:1 (metal:ligand) for Ti(IV) and Mo(VI), respectively. These metal ions interfere with the determination of each other in zero-order spectrophotometry. The first derivative spectra of these complexes permitted a simultaneous determination of Ti(IV) and Mo(VI) at zero crossing wavelengths of 500.0 nm and 455.0 nm, respectively. The effect of foreign ions in the determination of Ti(IV) and Mo(VI) were investigated. The proposed method has been successfully applied for the determination of titanium and molybdenum in standard alloy steel, mineral and soil samples.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Complexometric Titration: Overview
Complexometric EDTA Titration Curves

