Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

3D surface accuracy of CAD generated skull defect contour.

R J Winder1, W McKnight, I McRitchie

  • 1University of Ulster, United Kingdom.

Studies in Health Technology and Informatics
|January 13, 2006
PubMed
Summary

Computer-aided design (CAD) accurately generates skull defect contours for cranial implants. This technology minimizes deviations, improving cosmetic outcomes in reconstructive surgery.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

<math></math> Rn  emanation measurements for the XENON1T experiment.

The European physical journal. C, Particles and fields·2021
Same author

The first dual-phase xenon TPC equipped with silicon photomultipliers and characterisation with <math> </math>.

The European physical journal. C, Particles and fields·2020
Same author

Light Dark Matter Search with Ionization Signals in XENON1T.

Physical review letters·2020
Same author

Search for Light Dark Matter Interactions Enhanced by the Migdal Effect or Bremsstrahlung in XENON1T.

Physical review letters·2020
Same author

Tuberculosis screening at a diabetes clinic in the Republic of the Marshall Islands.

Journal of clinical tuberculosis and other mycobacterial diseases·2019
Same author

Constraining the Spin-Dependent WIMP-Nucleon Cross Sections with XENON1T.

Physical review letters·2019

Area of Science:

  • Neurosurgery
  • Biomedical Engineering
  • Medical Imaging

Background:

  • Cosmetic outcomes in cranial defect repair traditionally depend on surgeon's manual skill.
  • Computer-aided design (CAD) is increasingly adopted for custom cranial implant creation.
  • Accurate defect contouring is crucial for effective cranial implant design.

Purpose of the Study:

  • To validate the precision of CAD-generated skull defect contours.
  • To quantify the accuracy of CAD contours using 3D difference mapping.
  • To assess the suitability of CAD for producing accurate cranial implants.

Main Methods:

  • Utilized 3D multi-slice CT scanning on a life-size plastic skull model.
  • Generated surface models of the original skull and specific defects (temporofrontal, parietal).

Related Experiment Videos

  • Employed 3D difference maps to measure deviations between CAD contours and the original skull.
  • Main Results:

    • CAD contour deviations ranged from 0.0 mm to 2.0 mm.
    • Eighty percent of the total defect area exhibited less than 0.66 mm deviation.
    • The CAD-generated contours demonstrated high accuracy compared to the original skull.

    Conclusions:

    • CAD techniques provide highly accurate contours for cranial defect repair.
    • The minimal deviation achieved enables precise design and production of custom cranial implants.