Related Experiment Video
Updated: Aug 13, 2026

Atomic Force Microscopy Cantilever-Based Nanoindentation: Mechanical Property Measurements at the Nanoscale in Air and Fluid
Published on: December 2, 2022
[Observation of the L929 cell membrane after infrasound exposure with atomic force microscope]
Bing-shui Wang1, Jing-zao Chen, Bin Liu
1Department of Physiotherapy and Rehabilitation, Xijing Hospital, Fourth Military Medical University, Xi'an 710032, China.
Objective:
To observe the changes of L929 cell membrane with atomic force microscope (AFM) after infrasound exposure and to explore the mechanisms of effect of infrasound on cell membrane.
Methods:
After primary culture, the L929 cells were exposed to infrasound with intensity output of 130 dB and frequency of 16 Hz 2 hours each day for 3 days. The subsequent changes in the membrane of the control cells and the cells exposed to the infrasound were determined by nano-scale scanning with AFM.
Results:
After infrasound exposure, the normal prominence of the membrane became short and the dent became shallow in the 7.5 microm x 7.5 microm and 4.0 microm x 4.0 microm photographs. The prominence appeared as cobblestones. The surface of the membrane became smooth.
Conclusion:
The membrane structure of the L929 cells can be changed by infrasound exposure with intensity of 130 dB and frequency of 16 Hz. The change might be one of the characteristics of effect of infrasound on cell membrane.