Related Experiment Video
Updated: Aug 18, 2026

Classical Short-Delay Eyeblink Conditioning in One-Year-Old Children
Published on: September 1, 2018
A new technique to measure contrast sensitivity in human infants
R J Adams1, M E Mercer, M L Courage
1Memorial University of Newfoundland, St. John's, Canada.
Insights
This study introduces a faster, simpler method for measuring infant contrast sensitivity functions (CSFs). The new card procedure efficiently assesses visual development in infants aged 1 to 12 months.
Area of Science:
- Vision Science
- Developmental Psychology
- Pediatric Ophthalmology
Background:
- Infant visual development is crucial for cognitive and motor skill acquisition.
- Accurate measurement of contrast sensitivity functions (CSFs) is essential for assessing visual development.
- Previous methods for measuring infant CSFs were often time-consuming and complex.
Purpose of the Study:
- To introduce and validate a new, time-efficient procedure for obtaining binocular contrast sensitivity functions (CSFs) in infants.
- To assess the feasibility and effectiveness of the new card procedure across different infant age groups.
- To provide a simpler, more rapid, and cost-effective method for evaluating infant vision.
Main Methods:
- Utilized a novel card-based testing procedure with sine wave gratings of varying spatial frequencies and contrasts.
- Employed a rapid preferential looking (PL) technique, adapted from the Teller Acuity Cards, to gauge infant detection.
- Tested 80 infants across four age groups: 1, 3, 6, and 12 months.
Main Results:
- The new card procedure successfully obtained binocular contrast sensitivity functions (CSFs) in infants.
- Results indicated that the method is significantly simpler, faster, and more economical than existing techniques.
- The procedure demonstrated effectiveness across the tested infant age range, suggesting broad applicability.
Conclusions:
- The developed card procedure offers a practical and efficient approach to assessing infant contrast sensitivity.
- This method facilitates earlier and more frequent monitoring of visual development in infants.
- The findings contribute to a better understanding of early visual perception and its developmental trajectory.
Abstract:
We used a new time-efficient procedure to obtain binocular contrast sensitivity functions (CSFs) from 80 infants aged 1-, 3-, 6-, and 12-months-old. The test consisted of 5 sets of large (50 by 28 cm) cards constructed by mounting a 7.2 degrees circular sine wave grating with 1 of 5 spatial frequencies (0.3, 0.6, 1.2, 2.4, and 3.6 cpd at 60 cm) onto light gray matteboard. Each card also contained a second 7.2 degrees unpatterned patch of equal space-average luminance. Depending upon the set, the contrast within the gratings ranged from approximately 25 to 0.5%. To judge the subject's detection of each grating we used a rapid version of preferential looking (PL) similar to that developed for the Teller Acuity Cards. Results showed that compared to previous techniques, the card procedure allows one to estimate an infant's CSF much more simply, rapidly, and inexpensively.

