Related Experiment Video
Updated: Aug 13, 2026

Evaluating Therapeutic and Chemical Toxicity Using Organ-Cultured Porcine Corneas and Epithelial Wound Healing
Published on: January 10, 2025
The ex vivo pig eye as a replacement model for laser safety testing
James G Fyffe1, Thomas A Neal, William P Butler
1Uniformed Services University of the Health Sciences, Department of Preventive Medicine and Biometrics, Bethesda, Maryland, USA.
Abstract:
The purpose of this study was to evaluate the viability of ex vivo pig eyes as a replacement model for in vivo testing in the establishment of laser eye safety standards. Previous studies of pulsed energy absorption at 3.8 microm were performed using rhesus monkey cornea at pulse durations two orders of magnitude shorter than the 8-micros pulses used in the current study. Ex vivo pig eyes were exposed to laser pulses of various energies and then evaluated to establish the statistical threshold for corneal damage. Tissue analysis (histologic evaluation) was used to determine the extent of damage to the cornea. These results can be used in the establishment of safety standards for laser use; our findings also suggest that ex vivo pig eyes are suitable models for this purpose.