Related Experiment Video
Updated: Aug 15, 2026

Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
Arterial oxygen saturation during induction of anaesthesia and laryngeal mask insertion: prospective evaluation of
S R Haynes1, J R Allsop, G W Gillies
1Division of Anaesthesia, Victoria Infirmary, Langside, Glasgow.
Abstract:
In a prospective, randomized study of 87 patients, we have compared the incidence of hypoxaemia during induction of anaesthesia with subsequent Laryngeal Mask Airway (LMA) insertion in healthy adults when four different techniques were used: one without supplementary oxygen, and three with supplementary oxygen. Twelve patients did not receive supplementary oxygen before LMA placement, 25 underwent partial denitrogenation by breathing oxygen from the start of injection of the induction agent, 25 underwent formal denitrogenation by breathing oxygen for 3 min, and 25 received five tidal volume breaths of oxygen by face mask using positive pressure immediately after induction of anaesthesia. Anaesthesia was induced with propofol 2.0 mg kg-1 and fentanyl 1 microgram kg-1. Additional propofol was given if required. Arterial oxygen saturation was measured by pulse oximetry. Desaturation occurred in 11 of 12 patients who did not receive supplementary oxygen, and in 19 of 25 patients who received manual ventilation with 100% oxygen after induction of anaesthesia before LMA insertion. Full denitrogenation and partial denitrogenation were equally successful in preventing desaturation. Failure to position the LMA successfully occurred in 3% of patients, and some difficulty was encountered in another 18%.
Related Concept Videos
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques