Normal ambulatory blood pressure: a clinical-practice-based analysis of recent American Heart Association
Iddo Z Ben-Dov1, Liora Ben-Arie, Judith Mekler
1Department of Internal Medicine, Hadassah-Hebrew University Medical Center, Mount-Scopus Campus, Jerusalem, Israel. vp02292@netvision.net.il
Insights
New guidelines for blood pressure measurement show good agreement, but some individuals are classified as hypertensive by only one method. This discrepancy is more common with awake-sleep blood pressure readings.
Area of Science:
- Cardiology
- Hypertension Research
Background:
- The American Heart Association Council on High Blood Pressure Research established new recommendations for blood pressure measurement.
- Normal 24-hour ambulatory blood pressure is <130/80 mm Hg, normal daytime is <135/85 mm Hg, and normal nighttime is <120/70 mm Hg.
Purpose of the Study:
- To evaluate the compatibility of these new blood pressure cutoffs in clinical practice.
- To assess the agreement between 24-hour, daytime, and nighttime blood pressure measurements.
Main Methods:
- Analysis of 4121 ambulatory blood pressure measurement sessions.
- Classification of subjects based on 24-hour (<130/80 mm Hg) and awake-sleep (<135/85 mm Hg and <120/70 mm Hg) blood pressure criteria.
Main Results:
- A high concordance (92%, kappa=0.77) was observed between the different blood pressure measurement criteria.
- A small percentage of subjects (8%) showed discordant classifications.
- Discordance was more frequent for awake-sleep criteria (7%) than for 24-hour criteria (1%).
Conclusions:
- The new ambulatory blood pressure normality suggestions demonstrate good agreement in real-world clinical settings.
- A subset of patients may be classified as hypertensive based on only one measurement method, particularly the awake-sleep criteria.
- This discordance has implications for large-scale clinical blood pressure monitoring and patient management.
Purpose:
The American Heart Association Council on High Blood Pressure Research recently issued recommendations for blood pressure measurement in humans. According to these recommendations, normal 24-hour ambulatory blood pressure is defined as less than 130/80 mm Hg. Concurrently, normal daytime and nighttime blood pressure levels are defined as less than 135/85 mm Hg and less than 120/70 mm Hg, respectively. Our aim was to investigate the intrinsic compatibility of these blood pressure cutoffs in clinical practice.
Subjects And Methods:
We analyzed 4121 consecutive ambulatory blood pressure measurement sessions. Age was 57 +/- 7 years, 53% were female, and 64% and 9% were treated for hypertension and diabetes, respectively. Body mass index was 27 +/- 4 kg/m2, and manual blood pressure was 148 +/- 22/85 +/- 12 mm Hg. Subjects were classified as having normal 24-hour blood pressure if the corresponding value was less than 130/80 mm Hg. Normal awake-sleep blood pressure was diagnosed if awake blood pressure was less than 135/85 mm Hg and sleep blood pressure was less than 120/70 mm Hg.
Results:
Concordance between the cutoffs was found in 92% of the subjects (kappa = 0.77). Among the 8% of discordant subjects, only 1% were hypertensive applying the 24-hour (but not awake-sleep) blood pressure values, whereas 7% were hypertensive according to awake-sleep but not 24-hour blood pressure values (P <.0001).
Conclusions:
In real-life ambulatory blood pressure measurement, a generally good agreement was found between the recently issued ambulatory blood pressure normality suggestions. However, some subjects are classified as hypertensive only according to one of these methods, more often by the awake-sleep cutoff of 135/85 and 120/70 mm Hg. This discordance may be significant in large-scale clinical blood pressure monitoring.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Errors occurring during blood pressure monitoring
Several factors...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement