Related Experiment Video
Updated: Aug 10, 2026

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
Published on: February 9, 2022
Should forced expiratory volume in six seconds replace forced vital capacity to detect airway obstruction?
J E Hansen1, X-G Sun, K Wasserman
1Harbor-UCLA Medical Center, Box 405, 1000 W. Carson Street, Torrance, CA 90509, USA. jhansen@labiomed.org
Abstract:
It has been suggested that forced expiratory volume in six seconds (FEV(6)) should be substituted for forced vital capacity (FVC) to measure fractions of timed expired volume for airflow obstruction detection. The present authors hypothesised that this recommendation might be questionable because flow after 6 s of forced expiration from more diseased lung units with the longest time constants was most meaningful and should not be ignored. Furthermore, previous studies comparing FEV(6) and FVC included few subjects with mild or no disease. The present study used spirometric data from the USA Third National Health and Nutrition Evaluation Survey with prior published ethnicity- and sex-specific equations for FEV(1)/FEV(6), FEV(1)/FVC and FEV(3)/FVC, and new equations for FEV(3)/FEV(6), all derived from approximately 4,000 adult never-smokers aged 20-80 yrs. At 95% confidence intervals, 21.3% of 3,515 smokers and 41.3% of smokers aged >51 yrs had airway obstruction; when comparing FEV(1)/FEV(6) with FEV(1)/FVC, 13.5% were concurrently abnormal, 1.5% were false positives and 4.1% were false negatives; and when comparing FEV(3)/FEV(6) with FEV(3)/FVC, 11.6% were concurrently abnormal, 3.3% were false positives and 5.7% were false negatives. Substituting forced expiratory volume in six seconds for forced vital capacity to determine the fractional rates of exhaled volumes reduces the sensitivity of spirometry to detect airflow obstruction, especially in older individuals and those with lesser obstruction.
Related Concept Videos
Lung Capacity
Respiratory Volumes and Capacities I
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Respiratory Volumes and Capacities
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...

