Contact lens overrefraction variability in corneal power estimation after refractive surgery
Charlotte E Joslin1, James Koster, Elmer Y Tu
1Department of Ophthalmology and Visual Sciences, School of Public Health, Division of Epidemiology and Biostatistics, University of Illinois, Chicago, Illinois 60612, USA. charjosl@uic.edu
Journal of Cataract and Refractive Surgery
|February 14, 2006
Summary
The contact lens overrefraction (CLO) method
Area of Science:
- Ophthalmology
- Optometry
- Corneal Refractive Surgery
Background:
- Accurate corneal power measurement is crucial after refractive surgery.
- Traditional methods may be less reliable in post-keratorefractive surgery eyes.
- Contact lens overrefraction (CLO) offers an alternative approach.
Purpose of the Study:
- To assess the accuracy and precision of the CLO method for determining corneal refractive power.
- To compare CLO with historical methods in eyes post-myopic laser in situ keratomileusis (LASIK).
- To evaluate the impact of different rigid lens fitting strategies on CLO outcomes.
Main Methods:
- Prospective case series of 14 eyes from 7 subjects post-myopic LASIK with stable refractions.
- Comparison of CLO method with a historical corneal power prediction method.
- Evaluation of 4 rigid lens fitting strategies and 3 pupil scan sizes using cycloplegic CLO with Nidek OPD-Scan ARK-10000.
Main Results:
- CLO-estimated corneal power varied significantly based on lens fit.
- Bias between CLO and historical methods ranged from -0.38 to +2.42 D, differing from zero in most strategies.
- Precision varied substantially, with 95% limits of agreement ranging from 0.50 D to 2.59 D.
- Flat-fitting 9.0 mm diameter lenses yielded the least precise results.
Conclusions:
- The accuracy and precision of the CLO method in post-refractive surgery eyes are highly dependent on rigid lens fitting.
- A common clinical practice of flat-fitting 9.0 mm lenses resulted in the poorest accuracy and precision.
- Employing large-diameter lenses may enhance the outcomes of the CLO method.