Prediction of gas chromatographic peak width in capillary columns at different temperatures, carrier gas flows,
Kanit Krisnangkura1, Varaporn Pongtonkulpanich
1Biochemical Technology Division, School of Bioresources and Technology, King Mongkut's University of Technology Thonburi, Bangkok, Thailand. kanit.kri@kmutt.ac.th
Abstract:
Width factor (wf), relative band broadening (br) and retention factor are linearly correlated as ln wf = Inbr + ln k [Chromatographia (2002) 56, 99 -103]. The k and br are thermodynamic and kinetic energy parameters, and expanded to cover volumetric flow of carrier gas, temperature, phase ratio (beta) and carbon number (z). For columns of the same stationary phase and beta value but of different lengths, width at base (wb) can be predicted with the same numerical values of the constants. The average absolute differences between predicted and experimental wb for BP-1 columns of 30, 20 and 10 m are 1.27%, 1.21% and 1.37%, respectively. In predicting Wb of n-alkanes eluted from columns of the same stationary phase but of different ID, only the differences of ln beta are required for adjustment of one of the numerical values. The average absolute differences between Wb(cal) and Wb(exp) values for columns of 0.53, 0.32, 0.22 and 0.15 mm ID are 2.06, 3.67, 3.82 and 3.47%, respectively.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...