Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Simulation of peak position and response profiles in comprehensive two-dimensional gas chromatography
Siriluck Pojjanapornpun1, Chadin Kulsing2, Palathip Kakanopas3
1Division of Biochemical Technology, School of Bioresources and Technology, King Mongkut's University of Technology Thonburi (Bangkhuntien), Bangkok 10150, Thailand.
Abstract:
Approaches to simulate peak time and intensity profiles of compounds in comprehensive two dimensional gas chromatography (GC × GC) were developed, and which are demonstrated for separation of a mixture of saturated and unsaturated fatty acid methyl esters (FAME) using a range of column sets. The simulation of first and second dimension time (1tR and 2tR) of FAME relies on use of a Gibbs energy additivity approach to correlate with the structures of FAME. First and second dimension peak standard deviations (1σ and 2σ) of the compounds were further calculated from the 1tR and 2tR data according to the plate height concept which provided good agreement between the predicted and experimental peak widths at half height in one dimension GC (1DGC) with an overall R2 of 0.9628. The effect of 1σ distortion caused by the modulation process was also taken into account in the peak width simulation where the simulated 1σ data were rounded up to multiples of the scale of modulation period (PM). Two dimension Gaussian equations were then used to generate GC × GC results (2D contour plots) from simulated 1tR, 2tR, 1σ and 2σ data for FAME separation on different column sets employing ionic liquid and conventional columns. Good overall correlations between experimental and simulated 1tR and 2tR were obtained with R2 of 0.9951 and 0.9802, respectively, and the simulated 2D contour plots were an acceptable match with the experimental results.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....