Improved Chromatographic Alignment of GC-IMS Data Using Spectral Information
Luis Fernández1,2, Gema Guedes de la Cruz2, Eduardo Caballero2
1Department of Electronics and Biomedical Engineering, Universitat de Barcelona, 08028 Barcelona, Spain.
Abstract:
Gas chromatography-ion mobility spectrometry (GC-IMS) provides two-dimensional separation of volatile compounds, but instrumental variability can produce shifts and nonlinear distortions that hinder comparison among measurements. This study presents a chromatographic alignment workflow that uses spectral information from the drift-time dimension to support peak correspondence. The method combines injection point correction and parametric time warping along the retention-time axis with multiplicative correction of the drift-time axis. Peaks are then matched using information from both dimensions, and their retention positions are used as internal landmarks for a final cubic spline refinement without requiring standards specifically for alignment. The workflow was evaluated using 134 repeated measurements of a pooled urine sample and compared with correlation optimized warping (COW) applied directly and after different preprocessing stages. Conventional metrics based on correlation, Euclidean similarity, simplicity, and peak factor indicated comparable global performance for the proposed method and the best COW workflows. However, a correspondence-based assessment showed that high profile similarity and low positional dispersion did not necessarily imply preservation of the same peak correspondences. Direct COW recovered 45.2% of the reference correspondences, whereas recovery increased to 85.0% after injection point correction and to 89.9% after injection point correction plus parametric time warping. These results highlight the importance of combining profile-based metrics with measures of peak correspondence and show how the orthogonal drift-time dimension can provide additional constraints for chromatographic alignment in GC-IMS data.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
High-Resolution Mass Spectrometry (HRMS)
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.