Related Experiment Video
Updated: May 12, 2026

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
A biomechanical comparison of 2 techniques for reconstructing atrophic edentulous mandible fractures
Matthew J Madsen1, Richard H Haug
1College of Dentistry, University of Kentucky, Lexington, KY 40536-0297, USA.
Objectives:
The purpose of this investigation was to evaluate and compare the biomechanical behavior of 2 techniques for the reconstruction of atrophic edentulous mandible fractures.
Materials And Methods:
Thirty polyurethane atrophic edentulous mandible replicas (Sawbones, Vashon Island, WA) were used in this investigation (10 controls, 10 replicas of 2 different fixation techniques). The first reconstruction technique was a traditional titanium locking reconstruction plate affixed to the lateral border (buccal surface) of the mandible. The second reconstruction technique used the same type of plate, but placed it on the inferior border of the mandible. Both constructs were subjected to vertical loading at the symphysis and torsional loading at the body regions of the mandible replicas by an Instron 1331 (Instron, Canton, MA) servohydraulic mechanical testing unit. Mechanical deformation data within a 0-900 N range were recorded. Maximum load, displacement at maximum load, and stiffness were determined. Means and standard deviations were derived and compared for statistical significance using a Fisher's Protected Least Significant Differences Test with a confidence level of 95% (P < .05). Second- and third-order polynomial best-fit curves were also created for each group to further evaluate the mechanical behavior.
Results:
For symphysis loading, statistically significant differences were noted between the control group and both of the plating techniques for displacement at maximum load. However, no differences were noted between the experimental groups for displacement at maximum load, stiffness, or maximum load. For body loading, statistically significant differences were noted between the control group and the inferior border plating group for displacement at maximum load. However, no differences were noted between the experimental groups for displacement at maximum load, stiffness, or maximum load.
Conclusion:
During this bench top investigation, there were no significant differences noted in mechanical behavior between the 2 specific experimental groups for any of the conditions measured. When placed in the context of functional parameters, both of the plating techniques met or exceeded the requirements for loading.
Related Concept Videos
Restorative Care
Continuing Care
Nursing Process for Patient and Caregiver Teaching I: Assessment and Diagnosis
It is critical to determine the patient's learning needs during the assessment. Determination of learning needs compounds data from the...
Documentation in Long-Term and Home Healthcare Setting
Long-Term Care Facilities
Alzheimer's Disease: Overview
The clinical diagnosis of AD hinges on the presence of memory and other cognitive impairments. Biomarkers, such as changes in Aβ and tau...
Dementia
The progression of dementia is generally gradual.

