Related Experiment Video
Updated: Jul 24, 2026

Cutting Procedures, Tensile Testing, and Ageing of Flexible Unidirectional Composite Laminates
Published on: April 27, 2019
Compressive strength and compressive fatigue limit of conventional and high viscosity posterior resin composites
Letícia Brandão1, Gelson Luis Adabo, Luís Geraldo Vaz
1Department of Restorative Dentistry, Federal University of Santa Maria.
Abstract:
The purpose of this study was to compare the compressive strengths and compressive fatigue limits of three posterior composite resins (Filtek P-60, Surefil and Prodigy Condensable) and a universal restorative composite (Z-100). Cylindrical specimens (8 mm in length x 4 mm in diameter) were used. The dynamic test was performed using the staircase method, and the ratio between compressive fatigue limit and compressive resistance was also calculated (n = 15). The compressive strength and compressive fatigue limit data were analyzed by Anova and Tukeys test. The Z-100 composite demonstrated higher compression strength (307.20 MPa) than Surefil (266.93 MPa) and Prodigy Condensable (222.08 MPa). The resistance of Filtek P-60 (270.44 MPa) was similar to the resistances of Z-100 and Surefil, while Prodigy Condensable presented the lowest compressive strength. In the compressive fatigue limit tests, Filtek P-60 demonstrated a higher value (184.20 MPa) than Prodigy Condensable (155.50 MPa). Surefil (165.74 MPa) and Z-100 (161.22 MPa) presented limits similar to those of Filtek P-60 and Prodigy Condensable. The compressive fatigue limit/compressive strength ratio was 70.01% for Prodigy Condensable, 68.11% for Filtek P-60, 62.09% for Surefil and 52.48% for Z-100. It was concluded that the Z-100 universal composite was more sensitive to the dynamic test than the high viscosity materials.
More Related Videos
09:54Measuring the Mechanical Properties of Glass Fiber Reinforcement Polymer Composite Laminates Obtained by Different Fabrication Processes
Published on: June 30, 2023
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Fatigue
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Relation Between Tensile Strength and Compressive Strength of Concrete
Fatigue Strength of Concrete