Related Experiment Video
Updated: Sep 19, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Evaluation of Clinical Efficiency of Two Single-file Ni-Ti Rotary Systems in Performing Root Canal Treatment in
Lomada Lakshmidevi1, Penmetsa Ahalya1, Peddi Ravigna1
1Department of Pedodontics and Preventive Dentistry, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India.
Background:
The conventional procedure using stainless steel hand files is very time-consuming and has associated disadvantages. A literature review demonstrates the effectiveness of nickel-titanium (Ni-Ti) rotary files in this regard. Technological advancements have led to the development of various single-file Ni-Ti rotary systems, such as Kedo-S and XP-Endo Shaper.
Aim:
To compare the instrumentation time and quality of obturation in primary molars, assessed by the Coll and Sadrian criteria, using two single-file Ni-Ti rotary systems, Kedo-S and XP-Endo Shaper.
Materials And Methods:
A randomized clinical trial was conducted in children aged 4-9 years requiring single- or two-visit pulpectomy. A total of 50 primary molars were allocated into two groups of 25 each, that is, group I (Kedo-S) and group II (XP-Endo Shaper). Instrumentation time was recorded using a digital stopwatch, while the quality of obturation was assessed radiographically using the Coll and Sadrian criteria. The obtained data were subjected to statistical analysis using the Mann-Whitney U test for instrumentation time and Pearson's Chi-squared test for quality of obturation.
Results:
XP-Endo Shaper demonstrated a statistically significant difference in instrumentation time (p = 0.001) and a nonsignificant difference in the quality of obturation (p = 0.350). A greater percentage of optimal fills (84%) and a fewer number of voids were evident with XP-Endo Shaper.
Conclusion:
The use of the adaptive XP-Endo Shaper resulted in reduced instrumentation time and better quality of obturation.
Clinical Significance:
Pulpectomies performed under general anesthesia, where time is a constraint, can benefit from the use of single-file rotary systems. Considering the quality of obturation, XP-Endo Shaper performed better, with fewer voids and a greater number of optimal fills due to its adaptive technology.
Ctri Reg No:
CTRI/2025/04/084040.
How To Cite This Article:
Lakshmidevi L, Ahalya P, Ravigna P, et al. Evaluation of Clinical Efficiency of Two Single-file Ni-Ti Rotary Systems in Performing Root Canal Treatment in Primary Teeth: A Randomized Clinical Trial. Int J Clin Pediatr Dent 2026;19(8):987-993.