Related Experiment Video
Updated: Aug 11, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Endotracheal tube position in neonates requiring emergency interhospital transfer
P Mainie1, A Carmichael, S McCullough
1Neonatal Transfer Service for London, Barts and the London NHS Trust, London, United Kingdom.
Abstract:
A malpositioned endotracheal tube (ETT) is common following initial intubation. This study assessed ETT position in 53 orotracheally intubated neonates referred for interhospital transfer during a 3-month period. Position of the ETT on first chest radiograph (CXR) after intubation was assessed and related to radiographic lung expansion, with documentation that the final ETT length had achieved a satisfactory position. At the time of first CXR, median ETT length at the lips was 7.0 cm (range, 5 to 12 cm) with median tip position at T3.0 (range, C7 to T6). The ETT required repositioning in 58% of patients. Most malpositioned tubes were too low (26 were withdrawn and only four were advanced; p < 0.001), with lung expansion more closely related to vertebral than clavicular position of the ETT. Final ETT length correlated well with corrected gestation ( r = 0.83; p < 0.01) and marginally less well with weight ( r = 0.79; p < 0.01). From the regression analysis, we provide a table of recommended tube lengths by gestation.
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Cardiopulmonary Resuscitation II: ACLS Airway Management