Recent findings in the use of reflectance oximetry: a critical review
Brian F Keogh1, Robert J Kopotic
1Department of Anaesthesia & Intensive Care, Royal Brompton Hospital, London, UK. b.keogh@rbht.nhs.uk
Purpose Of Review:
Pulse oximetry is ubiquitous but detailed understanding of the technology is poor. This is illustrated by publications addressing knowledge of pulse oximetry and those warning against the use of transmission pulse oximeter sensors in a reflectance manner, unintended by the manufacturers, owing to the potential for iatrogenic problems. Reflectance oximetry sensors are distinct and their application rather specific. Users must adhere to the manufacturer's guidelines to be assured of approximating the claimed accuracy and other specifications. Moreover, a thorough understanding of the device's shortcomings will optimize performance and avoid misuse. Cautious skepticism is appropriate with use of any technology but particularly with indirect measures of vital signs.
Recent Findings:
The studies of reflectance sensors described here illustrate a diversity of successful applications and opportunities for further research. The genesis of applications for some sensors, for example fetal sensors, has proven helpful in other clinical settings where low mean arterial pressure and need for accurate monitoring of a SpO2 of less than 80% is poorly provided by transmittance sensors. Reflectance sensors are more prone to placement over contaminating sources (for example arteries and pigmentation), but their more sophisticated design can provide greater versatility than transillumination methods.
Summary:
This invited review highlights recent developments and applications of reflectance oximetry with an emphasis on the potential clinical and research advantages.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...