Related Experiment Video
Updated: Aug 10, 2026

Intra-cardiac Side-Firing Light Catheter for Monitoring Cellular Metabolism using Transmural Absorbance Spectroscopy of Perfused Mammalian Hearts
Published on: May 12, 2019
Polyhemoglobin with different percentage of tetrameric hemoglobin and effects on vasoactivity and electrocardiogram
Binglan Yu1, Zunchang Liu, Thomas Ming Swi Chang
1Artificial Cell and Organ Research Center, Faculty of Medicine, McGill University, Montreal, Quebec, Canada.
There has been considerable discussions on why some types of haemoglobin-based blood substitutes increase vasoactivity whereas a very few others do not. In this study, we prepare four different types of PolyHb each containing different percentage of tetrameric hemoglobin using glutaraldehyde crosslinking and characterized to ensure that they all have the same oxygen affinity. Thus the preparations are prepared from the same chemical method and have the same oxygen affinity. We infused these in the form of 1/6 volume toploading into anesthetized rats to simulate the use of blood substitutes in surgery. Mean arterial pressure (MAP) increased immediately after injection of PolyHb containing 38% or 78% of tetrameric hemoglobin. However, there was no significant increase in blood pressure with the injection of PolyHb containing 16% or 0.4% tetrameric hemoglobin. In electrocardiogram (ECG) study, we observe that high percentage (78%) of tetrameric hemoglobin causes marked changes in ECG immediately after infusion. Injection of PolyHb containing 16% or 38% of tetrameric hemoglobin resulted in minimal elevation of the ST segment. Infusion of PolyHb containing 0.4% of tetrameric hemoglobin did not result in any changes.
There has been considerable discussions on why some types of haemoglobin-based blood substitutes increase vasoactivity whereas a very few others do not. In this study, we prepare four different types of PolyHb each containing different percentage of tetrameric hemoglobin using glutaraldehyde crosslinking and characterized to ensure that they all have the same oxygen affinity. Thus the preparations are prepared from the same chemical method and have the same oxygen affinity. We infused these in the form of 1/6 volume toploading into anesthetized rats to simulate the use of blood substitutes in surgery. Mean arterial pressure (MAP) increased immediately after injection of PolyHb containing 38% or 78% of tetrameric hemoglobin. However, there was no significant increase in blood pressure with the injection of PolyHb containing 16% or 0.4% tetrameric hemoglobin. In electrocardiogram (ECG) study, we observe that high percentage (78%) of tetrameric hemoglobin causes marked changes in ECG immediately after infusion. Injection of PolyHb containing 16% or 38% of tetrameric hemoglobin resulted in minimal elevation of the ST segment. Infusion of PolyHb containing 0.4% of tetrameric hemoglobin did not result in any changes.
More Related Videos
Related Concept Videos
Hemoglobin
When all four heme groups are bound to oxygen, the resulting molecule is called oxyhemoglobin. As a result, arterial blood...
Oxygen Transport in the Blood
Pathophysiology of Cardiac Performance
Cardiomyopathy III: Hypertrophic Cardiomyopathy

