Related Experiment Video
Updated: Aug 10, 2026

Contrast Ultrasound Targeted Treatment of Gliomas in Mice via Drug-Bearing Nanoparticle Delivery and Microvascular Ablation
Published on: December 15, 2010
Microbubbles assist goat liver ablation by high intensity focused ultrasound
Tinghe Yu1, Xionglin Fan, Shuhua Xiong
1Institute of Ultrasound Engineering in Medicine, Chongqing Medical University, Chongqing, 400016, People's Republic of China. yutinghe@hotmail.com
Abstract:
High intensity focused ultrasound (HIFU) has been introduced to treat cancers. However, this therapy is a time-consuming procedure; destructing a deeper volume is also difficult as ultrasonic energy attenuates exponentially with increasing depth in tissues. The aim of the present study was to investigate the effects of introducing microbubbles on liver HIFU ablation. Seventeen goats were divided into groups A (n=8) and B (n=9). The livers in both groups were ablated using HIFU (1.0 MHz, 22,593 W/cm2) performed in the manner of a clinical regime using a clinical device. A microbubble agent was bolus-injected intravenously before HIFU exposure in group B. All animals in group A and seven goats in group B were euthanased to evaluate the ablation efficiency 24 h after HIFU. The necrosis rate (mm3/s), which was the volume of necrosis tissue per second of HIFU exposure, was used to judge the ablation efficiency. Pathological examinations were performed to determine whether there were residual intact tissues within the exposed volume. The other two goats in group B were used to determine the delayed pathological changes 7 days after ultrasonic ablation. The necrosis rate (mm3/s) was increased in group B (14.4647+/-4.1960 versus 33.5302+/-12.4484, P=0.0059). Pathological examinations confirmed that there were no residual unaffected tissue focuses within the exposed volume. Two remarkable changes occurred in the other two goats in group B 7 days after HIFU: there were ghost-cell islands at the periphery of the ablated tissues, and surrounding adjacent tissues outside the reactive zone necrotized. These findings showed that microbubbles could be used to assist liver HIFU ablation.
More Related Videos
08:02A High-Throughput Image-Guided Stereotactic Neuronavigation and Focused Ultrasound System for Blood-Brain Barrier Opening in Rodents
Published on: July 16, 2020
07:38Real-time Monitoring of High Intensity Focused Ultrasound (HIFU) Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound (HMIFU)
Published on: November 3, 2015