[Flow injection chemiluminescence method for the determination of phenol with N-bromosuccinimide-luminol system]

Ling-Yu Du1, Ning-Ning Ji, Shu-Hao Wang

  • 1Institute of Chemistry and Chemical Technology, Liaocheng University, Liaocheng 252059, China.

Related Concept Videos

Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene01:13

Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene

Bromination and chlorination of aromatic rings by electrophilic aromatic substitution reactions are easily achieved, but fluorination and iodination are difficult to achieve. Fluorine is so reactive that its reaction with benzene is difficult to control, resulting in poor yields of monofluoroaromatic products. To address this, Selectfluor reagent is used as a fluorine source in which a fluorine atom is bonded to a positively charged nitrogen.
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
Hydrolysis of Chlorobenzene to Phenol: Dow Process01:10

Hydrolysis of Chlorobenzene to Phenol: Dow Process

Simple aryl halides do not react with nucleophiles under normal conditions. However, the reaction can proceed under drastic conditions involving high temperatures and high pressure to give the substituted products. For example, chlorobenzene is converted to phenol using aqueous sodium hydroxide at 350 °C under high pressure by the Dow process. The reaction follows an elimination-addition mechanism involving a benzyne intermediate. Here, the chloride ion is eliminated to generate the benzyne...
Reactions at the Benzylic Position: Halogenation01:11

Reactions at the Benzylic Position: Halogenation

Benzylic halogenation takes place under conditions that favor radical reactions such as heat, light, or a free radical initiator like peroxide.