Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared
Published on: January 10, 2025
Two-photon absorption cross sections: an investigation of the accuracy of calculated absolute and relative values
Christian B Nielsen1, Sten Rettrup, Stephan P A Sauer
1Polymer Department, Riso National Laboratory, Frederiksborgvej 399, DK-4000 Roskilde, Denmark. chr@kiku.fk
Abstract:
We have studied the basis set and electron correlation effects on the ab initio calculations of two-photon absorption cross sections of water. Various series of correlation consistent basis sets up to triply augmented basis sets of valence pentuple zeta level as well as the popular 6-31G(d) basis set have been employed in combination with several coupled cluster, configuration interaction, and density functional theory methods. We find that it is very difficult to obtain converged values of the cross sections for even a small molecule such as water. Acknowledging these difficulties in obtaining a fully converged cross section for a given state, we also investigated the possibility of determining relative cross sections for a series of organic molecules. However, we did not find consistency between the relative cross sections calculated at the Hartree-Fock level and several coupled-cluster methods using the 6-31G(d) and aug-cc-pVDZ basis sets. However, we could reproduce the relative ordering of the two-photon absorption cross sections of the molecules studied at the Hartree-Fock level.
More Related Videos
10:03Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
Published on: June 27, 2014
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
UV–Vis Spectroscopy: Beer–Lambert Law
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Absorption of Radiation