Related Experiment Video
Updated: Aug 9, 2026

Closure of a Patent Foramen Ovale (PFO): An Intervention Sequence
Published on: December 23, 2022
Rupture of a synthetic VSD patch 28 years after total correction of Fallot's anomaly
Tobias Kühme1, Kåge Säfström, Niels Erik Nielsen
1Linköping Heart Center, University Hospital, Linköping, Sweden. tobias.kuhme@lio.se
Abstract:
Patients operated on for complex congenital heart malformations need continuous follow-up. We present a male patient born in 1948 with Fallot's anomaly. A total correction was performed when he was 21 years old. Twenty-eight years after the operation, at routine follow-up, he presented with a significant left-to-right shunt because of a new ventricular septal defect. During the operation we found the original patch to be fractured with a central perforation. The patient received a new patch and has been without any clinical symptoms since.