Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Exploration of coordination polymer as sorbent for flow injection solid-phase extraction on-line coupled with
You-Ya Zhou1, Xiu-Ping Yan, Ki-Nam Kim
1Key Laboratory of Functional Polymer Materials, The Ministry of Education of China, Research Center for Analytical Sciences, College of Chemistry, Nankai University, Tianjin 300071, China.
Abstract:
The copper(II) isonicotinate (Cu(4-C5H4N-COO)2(H2O)4) coordination polymer was prepared, characterized and explored as sorbent for flow injection solid-phase extraction on-line coupled with high-performance liquid chromatography (HPLC) for determination of trace polycyclic aromatic hydrocarbons (PAHs) in environmental matrices. Naphthalene, phenanthrene, anthracene, fluoranthene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene and benzo(ghi)perylene with various shape, size and hydrophobicity were used as model analytes. The porosity of the coordination polymer allows these guest PAHs molecules to diffuse into the buck structure, and the shape and size of the pores lead to shape- and size-selectivity over the guests. The precolumn packed with the coordination polymer was shown to be promising for solid-phase extraction of PAHs in environmental samples with subsequent HPLC separation and UV detection. With extraction of 50 ml of sample solution, the enhancement factors for the PAHs studied ranged from 200 to 2337, depending on the shape, size and hydrophobic property of the PAHs. The detection limits (S/N = 3) of 2-14 ng l(-1) and the sample throughput of 3 samples h(-1) were obtained. The developed method was applied to the determination of trace PAHs in a certified reference material (coal fly ash) and local water samples.
More Related Videos
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Analyte Adsorption and Distribution